This page explains the steps to take for installing a glass countertop. The process steps below will outline the process for a standard glass (clear, illusion, backpainted) countertop on a component, and an applied (layered) glass countertop on a standard TFL countertop. Prior to beginning the installation, ensure you completed all steps of installing the system skeleton and all elements below the countertop.

Page Contents

Skill Requirements
Tools & Hardware
Installation Steps
Related Training Materials
Final Steps & Delivery
Certification
Tips from the Field
Terms & Definitions
BOM Codes


Anchor
Skill-Requirements
Skill-Requirements
Types of Installation: Off-the-Floor, Floor-Based, Wall Bed

Installer Level Required: Journeyman Installer

Products Required: Special Order

Back to top


Anchor
Tools-&-Hardware
Tools-&-Hardware
Tools Required

image-20240304-211941.png

Utility Knife

image-20240304-212006.png

Glass Cleaner

image-20240304-212032.png

Rags

Hardware Required

image-20240304-212140.png

VHB Tape Circles

Back to top


Anchor
Installation-Steps
Installation-Steps
Title

Panel
panelIconId1f9ba
panelIcon:safety_vest:
panelIconText🦺
bgColor#FFFAE6

Personal Protective Equipment (PPE) must beworn at all times when handling material and operating the power tools mentioned throughout this process. Review the PPE Matrix for further guidance.

Glass Countertop Installation

Coming Soon

Applied (Layered) Glass Countertop Installation

  1. Ensure the component and or countertop below the glass countertop have been installed.

  2. Dry fit the glass countertop and ensure it is the same size as the TFL countertop on the componentcomponent or countertop below. If it is not, reach out to your manager.

  3. Place a VHB tape circle in each corner of the TFL countertopmaterial below.

Expand
titleClick for more information
  • If the top is larger than 24” in either direction, place a VHB circle every 24 - 30” around the perimeter.

  1. Using glass cleaner, wipe down the bottom of the glass countertop.

  2. Peel the protective coating off each VHB circle.

  3. Place the glass countertop on top of the component or TFL countertop.

Expand
titleClick for more information
  • Depending on the size and weight of the countertop, a second team member may be required to assist. A team lift is required if the glass countertop is larger than 36” in width or length, or if it is heavier than 48lbs.

  • Ensure the countertop is in the desired location before setting it down on the VHB tape.

  1. Apply pressure in each tape location to ensure the glass countertop is adhered.

  2. Wipe the top of the glass countertop with glass cleaner.

Back to top


Anchor
Related-Training-Materials
Related-Training-Materials
Related Training Materials

Skeleton Fundamentals
Complete the Installation
System Touch Ups
Cleaning the System & Jobsite
Delivery to the Customer
PPE Matrix

Back to top


Anchor
Final-Steps-&-Delivery
Final-Steps-&-Delivery
Final Steps & Delivery

  1. Inspect the installation and complete any touch ups if necessary.

  2. If there are no more components to install, remove all stickers/labels.

  3. If there are no more components to install, complete the clean up process.

  4. If there are no more components to install, complete the Professional Installation Experience by walking through the space with the customer and deliveringthe final product.

Back to top


Anchor
Certification-Steps
Certification-Steps

Panel
panelIconId270d
panelIcon:writing_hand:
panelIconText✍️
bgColor#E3FCEF

Certification Steps:

  1. VHB tape circles are placed in every corner and, if applicable, every 24 - 30” around the perimeter of the TFL countertop.

  2. The glass is wiped down before and after it is placed in position.

  3. If applicable: Assistance in lifting and placing was provided.

Back to top


Anchor
Tips
Tips
Tips from the Field
Tips submitted by fellow installers and leaders in the field. These optional tips are intended to make this install process simpler.

Panel
panelIconId1f5e3
panelIcon:speaking_head:
panelIconText🗣️
bgColor#DEEBFF

Click here to submit your own tip from the field.

Back to top


Anchor
Terms
Terms
Terms & Definitions

BOM

Bill of Materials; Parts List

Dry Fit

Holding material or accessory in its intended location to test size accuracy.

Back to top


Anchor
BOM
BOM
BOM Codes
The purpose of this section is to provide guidance when confirming details on the BOM. This list includes all individual parts typically associated with this process.

PNL

Applied Panel

The codes in the table above are directly from the Corporate CAD database and may not reflect all codes included in the Supported Franchise Database or Independent Franchise Databases.

Back to top