03. Skeleton Fundamentals
This page explains the steps to take for leveling, plumbing, and securing a system skeleton. This explains the process for off-the-floor systems. For floor-based systems, refer to the floor-based page. Prior to beginning this process, ensure you completed all steps to build the system skeleton.
Page Contents
Skill Requirements
Tools & Hardware
Process Steps
Related Training Materials
Next Steps
Certification
Tips from the Field
Terms & Definitions
Types of Installation: Off-the-Floor, Wall Bed
Installer Level Required: Jr. Apprentice Installer
Products Required: TFL Material
Stud Finder
Drill Driver/Impact Drill
4' Level
3/16” Drill Bit
Hardware Required
2 1/2” Screw
Metal EZ Anchors
Personal Protective Equipment (PPE) must be worn at all times when handling material and operating the power tools mentioned throughout this process. Review the PPE Matrix for further guidance.
Ensure all top, bottom, and middle fixed shelves have been installed.
Level system from the high spot in the room. Slide your level across the top of the system and adjust the partition suspension brackets accordingly.
Plumb the system from front to back and left to right using a 2 or 4-foot level to ensure it is square.
If partitions are longer than 6 feet, check for plumb in two spots: high and low.
When prepping the partitions, ensure corner brackets are installed on the partitions.
Check for studs.
Close the corner bracket caps.
Tighten the front (in/out) of the suspension bracket to the wall.
Repeat Steps 3 and 4 for all partitions.
Snap on suspension bracket covers over all suspension brackets.
Skeleton Fundamentals
Floor-Based Systems
PPE Matrix
Product Feedback Form
Complete the Installation
Touch-Up and Quality Check System
Cleaning the System & Jobsite
System Delivery
Tips from the Field
Tips submitted by fellow installers and leaders in the field. These optional tips are intended to make this install process simpler.
Click here to submit your own tip from the field.
Level | The wall or system is horizontally straight. |
Plumb | The wall or system is vertically straight. |
Skeleton | The foundation of a wall-hung or floor-based system. This typically consists of rail, partitions, fixed shelves, and connecting shelves. |